Influence of hydroxybosentan on determination of bosentan in human plasma
- Published
- Accepted
- Subject Areas
- Clinical Trials, Pharmacology
- Keywords
- hydroxybosentan, bosentan, human plasma
- Copyright
- © 2015 Gilant et al.
- Licence
- This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, reproduction and adaptation in any medium and for any purpose provided that it is properly attributed. For attribution, the original author(s), title, publication source (PeerJ PrePrints) and either DOI or URL of the article must be cited.
- Cite this article
- 2015. Influence of hydroxybosentan on determination of bosentan in human plasma. PeerJ PrePrints 3:e1539v1 https://doi.org/10.7287/peerj.preprints.1539v1
Abstract
Bosentan is a drug used in the treatment of pulmonary arterial hypertension. Evaluation of bosentan pharmacokinetics is an important step of the drug development. The aim of our study was to evaluate bioanalytical method reliability by assessing the influence of metabolite on the determination of bosentan in human plasma. In human body, bosentan is converted to three metabolites. Hydroxybosentan is an only pharmacologically active metabolite and its maximum concentration in plasma reaches 5-8% of the bosentan’s maximum concentration. Hydroxybosentan’s elimination half-life was reported to be very similar to that of bosentan (5-6 h) or slightly greater (6-14 h). It was observed that times to reach the maximum concentrations are similar for both compounds. Combination of high-performance liquid chromatography with UV-Vis detection and liquid-liquid extraction enabled to was determine bosentan in human plasma in the range of 50-4000 ng∙mL-1. During the method validation, metabolite back-conversion was studied using human plasma samples spkied with hydroxybosentan to obtain concentration of 500 ng·mL-1. Additionally, the influence of metabolite on extraction of bosentan and the internal standard was assessed. We found that there was no influence of metabolite on determination of bosentan in developed bioanalytical method. The method was validated according to European Medicines Agency (EMA) and Food and Drug Administration (FDA) guidelines, in compliance with the principles of Good Laboratory Practice (GLP). All of the validation parameters met acceptance criteria what confirmed method’s reliability.
Author Comment
This is an Abstract submitted to the X MKNOL Conference.