Multimode ultrasonic technique is recommended for the differential diagnosis of thyroid cancer

View article
PeerJ

Main article text

 

Introduction

Materials and Methods

Patients

B-mode examination

SWE-mode examination

CEUS-mode examination

Statistical analysis

Results

The diagnostic value of single-mode ultrasonic techniques for differentiating benign from malignant thyroid nodules

The diagnostic value of multimode ultrasonic techniques for differentiating benign from malignant thyroid nodules

Discussion

Conclusions

Supplemental Information

Comparison of the quantitative elasticity values of SWE between benign versus malignant thyroid nodules.

SWE, Share Wave Elastography; E_max, maximum elasticity; E_mean, mean elasticity; E_SD, Standard deviation SWE; E_ratio, ratio of elasticity mean twice.

DOI: 10.7717/peerj.9112/supp-1

ROC curve analysis of elasticity values obtained from SWE for differentiating thyroid nodules.

SWE, share wave elastography; AUC, the area under a receiver operating characteristic (ROC) curve.

DOI: 10.7717/peerj.9112/supp-2

Simple logistic regression of each characteristic of 2D US for the prediction of benign versus malignant thyroid nodules.

2D US: two dimensional ultrasound; B, the estimated logistic coefficient; SE, the standard error of the coefficient; OR, odds ratio; A/T, anteroposterior/transverse diameter.

DOI: 10.7717/peerj.9112/supp-3

Multiple logistic regression of the four significant characteristics obtained from 2D US for the prediction of benign versus malignant thyroid nodules.

2D US: two dimensional ultrasound; B, the estimated logistic coefficient; SE, the standard error of the coefficient; OR, odds ratio; A/T, anteroposterior/transverse diameter.

DOI: 10.7717/peerj.9112/supp-4

Multiple logistic regression of 2D US combined with CEUS for the prediction of benign versus malignant thyroid nodules.

2D US: two dimensional ultrasound; B, the estimated logit coefficient; SE, the standard error of the coefficient; OR, odds ratio; A/T, anteroposterior/transverse diameter; CEUS, contrast enhance ultrasound.

DOI: 10.7717/peerj.9112/supp-5

Multiple logistic regression of 2D US combined with SWE for the prediction of benign versus malignant thyroid nodules.

2D US: two dimensional ultrasound; CEUS, contrast enhance ultrasound; SWE, share wave elastography; B, the estimated logit coefficient; SE, the standard error of the coefficient; OR, odds ratio; A/T, anteroposterior/transverse diameter; E_mean, one elasticity value of SWE.

DOI: 10.7717/peerj.9112/supp-6

Multiple logistic regression of 2D US combined with CEUS and SWE for the prediction of benign versus malignant thyroid nodules.

2D US: two dimensional ultrasound; CEUS, contrast enhance ultrasound; SWE, share wave elastography; B, the estimated logistic coefficient; SE, the standard error of the coefficient; OR, odds ratio; A/T: anteroposterior/transverse diameter; E_mean, one elastic value of SWE.

DOI: 10.7717/peerj.9112/supp-7

Raw data.

A total of 196 thyroid nodules from 185 patients were analyzed in this study.

DOI: 10.7717/peerj.9112/supp-8

R code for the statistical analysis.

DOI: 10.7717/peerj.9112/supp-9

Additional Information and Declarations

Competing Interests

The authors declare that they have no competing interests.

Author Contributions

Juan Wang conceived and designed the experiments, performed the experiments, analyzed the data, prepared figures and/or tables, authored or reviewed drafts of the paper, and approved the final draft.

Xin He performed the experiments, prepared figures and/or tables, and approved the final draft.

Li Ma performed the experiments, prepared figures and/or tables, and approved the final draft.

Miao Li analyzed the data, prepared figures and/or tables, and approved the final draft.

Lei Sun analyzed the data, prepared figures and/or tables, and approved the final draft.

Jue Jiang conceived and designed the experiments, authored or reviewed drafts of the paper, and approved the final draft.

Qi Zhou conceived and designed the experiments, authored or reviewed drafts of the paper, and approved the final draft.

Human Ethics

The following information was supplied relating to ethical approvals (i.e., approving body and any reference numbers):

Xi’an Jiaotong University granted Ethical approval to carry out the study within its facilities (No. 2018200).

Data Availability

The following information was supplied regarding data availability:

The raw measurements are available in Table S8 and Note S1.

Funding

This work was supported by the National Natural Science Foundation of China (No. 81871366). The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.

11 Citations 1,337 Views 465 Downloads