Review History


All reviews of published articles are made public. This includes manuscript files, peer review comments, author rebuttals and revised materials. Note: This was optional for articles submitted before 13 February 2023.

Peer reviewers are encouraged (but not required) to provide their names to the authors when submitting their peer review. If they agree to provide their name, then their personal profile page will reflect a public acknowledgment that they performed a review (even if the article is rejected). If the article is accepted, then reviewers who provided their name will be associated with the article itself.

View examples of open peer review.

Summary

  • The initial submission of this article was received on July 5th, 2023 and was peer-reviewed by 3 reviewers and the Academic Editor.
  • The Academic Editor made their initial decision on October 9th, 2023.
  • The first revision was submitted on December 5th, 2023 and was reviewed by the Academic Editor.
  • The article was Accepted by the Academic Editor on January 17th, 2024.

Version 0.2 (accepted)

· Jan 17, 2024 · Academic Editor

Accept

I should request that you correct the text for minor language issues. Please change "In specific" to "Specifically" in lines 100, 228, and 262.

[# PeerJ Staff Note - this decision was reviewed and approved by Mike Climstein, a PeerJ Section Editor covering this Section #]


**PeerJ Staff Note:** Although the Academic and Section Editors are happy to accept your article as being scientifically sound, a final check of the manuscript shows that it would benefit from further English editing. Therefore, please identify necessary edits and address these while in proof stage.

Version 0.1 (original submission)

· Oct 9, 2023 · Academic Editor

Major Revisions

Two reviewers have recommended that you revise and resubmit your manuscript. One of the issues that was raised by the reviewers is the need to provide some discussion for the clinical motivation and justification of the proposed method of arthrodesis. The choice of substitute materials rather than cadaver bones should be addressed. Are you able to compare some of the basic biomechanical properties of your printed bone substitutes to the bones themselves? You state that the stiffness of the synthetic bone is comparable to the stiffness of real bones (lines 271-272) but do not provide a reference. What about the fracture properties? Without such information the wording in the discussion and conclusion should be more cautionary and should include a statement of limitations requiring further work with cadaver tissue. This may be especially relevant to the data in Table 5 and Figure 5 and to statements regarding "safe levels of loading (line 38)?

In your introduction lines 51-53 you state that prior results have suggested that a medial plate may provide better stability than a dorsal plate. Shouldn't you circle back to this question in your discussion and conclusions?

I also recommend modifying the text where the word 'fused' is used. I find this confusing. Perhaps you could describe this as a fixation construct to achieve arthrodesis or bone fusion. In the Materials and Methods section, line 79 please insert the word 'virtually': "Then the bone surfaces in the MTP-1 joint were 'virtually' cut to ..." In the Data Analysis section, line 125 and in Table 2 please add 'flexural' between initial and stiffness.


**PeerJ Staff Note:** Please ensure that all review, editorial, and staff comments are addressed in a response letter and any edits or clarifications mentioned in the letter are also inserted into the revised manuscript where appropriate.

·

Basic reporting

Good standard of English language. Satisfactory background, methodology and analysis of results.

Experimental design

Good design and hypothesis. Use of 3d printed models is a limiting factor, but mentioned by authors. However, cadaveric specimens are also limited. Good presentation of results.

Validity of the findings

Findings justified, however authors tempted to suggest medial plating with an interfragmentary screw is a safe option despite results suggesting dorsal plating with inter fragmentary screw was superior.

·

Basic reporting

This article is clearly written, using professional English throughout.
The Literature references are sufficient. Data are shared and the figures and tables are comprehensive

Experimental design

The primary aim of the study is well stated. However from a clinical/patient perspective you could question whether the experimental design is meaningful and/or relevant.
In current clinical practise the use of a plate and lag screw has been widely introduced. The use of a medial plate is from patient perspective not desirable.
In addition the indication for this procedure is of mucht more importance compared to the fixation type.

Validity of the findings

The novelty is limited.
All underlying date are robust but of less adede value. The research techniques are robust and statistically sound. However the implications for clinical use are limited, due to the model and the patient perspective.

Additional comments

Authors should consider the effect of this fixation type in relation to currently widley used techniques. Inclusion of a patient study group would be very important, inclusion of patient perspective is essential.

Reviewer 3 ·

Basic reporting

Please refer the reviewer comments document.

Experimental design

Please refer the reviewer comments document.

Validity of the findings

Please refer the reviewer comments document.

Additional comments

Please refer the reviewer comments document.

Annotated reviews are not available for download in order to protect the identity of reviewers who chose to remain anonymous.

All text and materials provided via this peer-review history page are made available under a Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.